TH Hill DS 1 Category 1 - 5 Inspection |
|
|
|
Method No. |
Description |
|
01 |
Visual Pipe Inspection |
|
02 |
OD Inspection |
|
03 |
UT wall thickness measurement |
|
04 |
EMI with Longitudinal field (Transverse flaw detection by Spectagraph-2000) |
|
05 |
EMI with Longitudinal field and Gamma ray wall thickness measurement (Scanalog-100
+ Scanawall) |
|
06 |
MPI Slip/ Upset using active field AC Yoke Dry MPI |
|
07 |
UT Slip/ Upset inspection
|
|
08 |
Elevator Grooves inspection
|
|
09 |
Visual Connection
|
|
10 |
Dimensional inspection of Box OD, Pin ID, shoulder width, tong space and Box counter
bore.
|
|
11 |
Method no.10 plus Pin lead, counter bore depth, pin flat length, bevel diameter,
seal width and shoulder flatness.
|
|
12 |
Dimensional inspection of Box OD, Pin ID, pin lead, bevel dia, pin stress relief
diameter and width, boreback cylinder dia and thread length and HWDP center upset
diameter.
|
|
13 |
Black light inspection with Fluorescent wet MPI using active DC current.
|
|
14 |
UT connection
|
|
15 |
Liquid Penetrant Inspection
|
|
|
|
CATEGORY WISE INSPECTION PROGRAMME |
|
Product |
Category-1
|
Category-2 |
Category-3 |
Category-4 |
Category-5 |
|
Toll Joint |
Method 9
|
Method 9, 10 |
Method 9, 10 |
Method 9, 11 |
Method 9, 11, 13 |
|
Drill Pipes |
Method 1 |
Method 1, 2, 3 |
Method 1, 2, 3, 4 |
Method 1, 2, 3, 4, 6 |
Method 1, 2, 4, 5, 6, 7 |
|
Drill Collar |
Method 8, 9 |
Method 8, 9, 13 |
Method 8, 9, 12, 13 |
Method 8, 9, 12, 13 |
Method 8, 9, 12, 13 |
|
HWDP |
Method 1 |
Method 1 |
Method 1, 6 |
Method 1, 6 |
Method 1, 6 |
|
|